Three Phase 10KVA IGBT Double Conversion Low Frequency Online UPS

Brand Name : G-Tech

Model Number : GP33 Series

Certification : CE, ROHS, ISO, UL

Place of Origin : China

MOQ : 1

Payment Terms : Western Union, L/C, T/T

Supply Ability : 200 pcs per month

Delivery Time : 20-30 days

Application : Office, Computer facilities, Security, Monitoring, Alarm,Telecommunications, Medical, Instrumentation, financial

Type : On-line, Low frequency online, 3 phases in 3 phases out

Product Name : Three Phase Online UPS, 10KVA-300KVA IGBT DSP Double Conversion UPS, low frequency UPS

Battery type : Sealed Lead Acid Maintenance Free

Frequency : 50/60hz

Power factor : >=0.9

Protection : Short Circuit,Overvoltage,Unbalanced Loads,Overcurrent

Phase : Three Phase

Price : Negotiation

Contact Now

Three Phase Online UPS, 10KVA-300KVA IGBT DSP Double Conversion UPS, low frequency UPS

10KVA-300KVA Low Frequency Online Double Conversion UPS Power Supply System, Three-phases In/ Three-phases Out

Three Phase Online UPS, 10KVA-300KVA IGBT DSP Double Conversion UPS, low frequency UPS, Uninterruptible Power Supply for data center, computer room, etc.​

Product Introduction
GP33 series is online double conversion UPS, with Isolated Gate Bipolar Transistors(IGBT) that performs excellent conversion of sinewave output from high frequency PWM inverter. The series is applicalbe to small and medium-sized data centers, network management center, computer rooms for enterprises, and able to provide solutions to conditions like voltage instantaneous drop-off or damping concussion, high-voltage pulse, voltage pulsation, surge voltage, harmonic, distortion and frequency fluctuation, it guarantees to offerr safe and reliable power supply for any loads to users.

Feature



1> High-efficient DSP chip

2> Outstanding electric property

3> Good looking and excellent hardware

4> N+1 parallel redundancy(compatible to battery share in the parallel mode)

5> Frontal-board operation and maintenance

6> Twin-channel line input

7> Remote monitoring

8> Intelligent management of battery charging and discharging

9> Flexible battery arrrangement

10> Flexible arrangement, change due to the need

11> Built-in lightning protection module

Specification

MODEL GP33-10-20KS GP33-30-40KS GP33-60-80KS GP33-100-120KS GP33-160-200KS GP33-250-300KS
Capacity 10/15/20Kva 30/40Kva 60/80Kva 100/120Kva 160/200Kva 250/300Kva
UPS(L*W*D) 402x660x880 412x813x1121 505x1060x1321 555x1060x1421 1043x1160x1748 1600x1182x1962
Pack (L*W*D) 505x800x1030 515x926x1270 603x1190x1486 653x1190x1586 1303x1180x2076 1760x1301x2168
UPS weight (kg) 153/168/194 223/256 382/434 535/580 1120/1320 1540/1745
Temperature 0~40
Humidity 0~95% non condensate
Noise <60dB @1.5m from surface of unit
Altitude 1000m(height rises every 100m, power decreases 1%, maximum height is 4000m)
Efficiency Power saving mode>98%, Inverter>92%, AC-AC91%
Transference 0ms cutless
Technology True double-conversion online technology conversion performed by IGBT
Input
Voltage 3*220/380 vac ± 25%
Frequency 50Hz ± 15%
Conductors Three Phases + N + E
Output
Voltage (selectable) 3*220/380 vac ± 1%
Frequency 50Hz ± 0.1%
Waveform Pure sine wave generated by high frequency PWM inverter
Harmonic Distortion <2% Linear Load / <5% Nonlinear Load
Crest Factor 3:1
Power Factor 0.8 or 0.9
Overload Recuperation Automatic transfer to normal
Voltage Regulation Load balance: ± 1%
Overload Capacity 125% for 12 minutes/ 150% for 1 minute
Conductors Three Phases + N + E
Battery
Type Maintenance-free sealed lead-acid battery, 12V*32 batteries
Full load autonomy 3 to 15 minutes, extended-range capacity
Typical recharge time 4~8 hours, 90%
Battery behavior Autotest, Transfer Point Adjustable battery and alarm setting
Battery protection Fuse protection, battery switch, temperature compensation, regular inspection, software protection, overvoltage tripping.
Rectification Software protection, input switch, over current protection, temperature protection.
Protection
Hardware protections Breaker for input, output, battery and bypass. Fast acting fuses in DC, fans, redundant power supplies, temperature sensors, on-o switch and audible alarms.
Bypass Static solid state, automatic and manual operation without interruption for maintenance. External Bypass(optional)
Emergency switch Remote and/or local EPO
Supervisory control and communication
Frontal panel Interactive LCD display(Touchscreen)
Alarms Audible and visual alarm for abnormal conditions
Communications RS232, SNMP-RJ45, GPRS (RS232 & RJ45 standard, the other is optional)

  • Three Phase 10KVA IGBT Double Conversion Low Frequency Online UPS

Specifications & Main Models

  • Three Phase 10KVA IGBT Double Conversion Low Frequency Online UPS
  • Three Phase 10KVA IGBT Double Conversion Low Frequency Online UPS

Product Tags:

10KVA Low Frequency Online UPS

      

DSP Low Frequency Online UPS

      

IGBT online double conversion ups

      
China Three Phase 10KVA IGBT Double Conversion Low Frequency Online UPS wholesale

Three Phase 10KVA IGBT Double Conversion Low Frequency Online UPS Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: G-TECH POWER GROUP
*Subject:
*Message:
Characters Remaining: (0/3000)